OUR MISSION

 

To deliver world-class, high-quality and effective testing services, design optimization, R&D support and patient-specific simulated-use systems.

 

  • Models for physician training

  • Models for biomedical engineering

  • Models for sales demonstrations

  • Clinical education support

Medical Implant Mechanics LLC (MIM) is a California-based company founded in 2006. We aim to give customers the most advanced, highest-quality and timely mechanics solutions and services, both analytical and experimental. MIM provides structural finite element analysis (FEA), computational fluid dynamics (CFD) and customized mechanical testing across a range of implantable medical devices, including stents, filters, stented grafts, heart valves, transcatheter valves and orthopedic products. Our broad FEA, CFD and experimental expertise is combined with our knowledge of materials and devices to deliver the best-quality designs before the device prototyping process begins.

 

FATIGUE AND DURABILITY TEST PLATFORMS

 

Our MIM Irvine facility houses a range of fatigue and durability testing platforms, including dynamic and static test machines, fatigue test machines and valve durability testers. Testing can be performed on stents, heart valves, soft tissues, elastomers, biofilm, medical structure units and orthopedic medical apparatus and instruments. MIM also offers material evaluation services such as tensile tests per ASTM E8 and F2516, breakdown potential testing per ASTM F2129 and transformational temperature testing.
 

MIM provides particulate testing to demonstrate device coating integrity — for example, confirming that a guidewire’s coating stays intact and does not shed particulate material under simulated worst-case use conditions.

 

MIM performs cyclic potentiodynamic polarization testing per ASTM F2129 to assess the corrosion susceptibility of implantable medical devices. We run corrosion tests on implantable devices to evaluate potential pitting, crevice, galvanic or fretting effects arising from the device design.
 


VASCULAR DIVISION

 

MIM’s new Vascular Division designs custom anatomical 3D models from patient-specific DICOM/CT data or MRIs, using a variety of 3D materials along with silicone, acrylics and polyurethanes. MIM has also developed a dry lubricant coating called Vessel Glide, engineered to make silicone models lubricious while keeping them transparent.


Also new from MIM is the Portable Pulsatile Pump, which brings our silicone models to life. The SHS-1000 is a low-cost alternative to portable pulse duplicators currently on the market, and its light weight makes it well suited to sales demonstrations and physician training. The SHS-2000 Pulse Duplicator adds data acquisition and storage plus arbitrary waveform capability, and is designed for R&D. 

 

 

From structural FEA and CFD to fatigue, corrosion and particulate testing, MIM brings analytical and experimental methods together under one roof. Our Irvine facility supports implantable device programs from early design optimization through simulated-use evaluation, while our Vascular Division supplies anatomical models and pulsatile pumps for training, demonstration and R&D.